• Call Now 020 24465871
  • Email Now apcorp1999@gmail.com

We are the best supplier of Control Panels.

There are Jalganga control panels available for submerged pump sets that are single or three phase. Capacitors for beginning and running are found in panels. While running capacitors guarantee smooth motor operations, starting capacitors supply the torque needed to start the motor. Depending on the motor rating, a range of start and run capacitors is offered. A voltage tester is also included for monitoring the input voltage.

We Provides below categories of Control Panels :

MONO

Features :
  • Over Load Protection
  • On Off by MCB
Specifications :
  • Voltage : 120 to 250 Volts A.C
  • H.P : 0.5 to 3.0 H.P

MCBWS

Features :
  • Over Load Protection
  • On Off by MCB
  • With AMP and Volt Meter
Specifications :
  • Voltage : 120 to 250 Volts A.C
  • H.P : 0.5 to 3.0 H.P

MCBWS (DIGI)

Features :
  • Over Load Protection
  • On Off by MCB
  • With AMP and Volt Meter Digital
Specifications :
  • Voltage : 120 to 250 Volts A.C
  • H.P : 0.5 to 3.0 H.P

O/F (DIGI)

Features :
  • Over Load Protection
  • On Off by MCB
  • With AMP and Volt Meter Digital
Specifications :
  • Voltage : 120 to 250 Volts A.C
  • H.P : 0.5 to 3.0 H.P

CH+OLP

Features :
  • Over Load Protection
  • With AMP and Volt Meter
Specifications :
  • Voltage : 120 to 250 Volts A.C
  • H.P : 0.5 to 2.0 H.P

CH+MCB

Features :
  • Over Load Protection
  • On Off by MCB
  • With AMP and Volt Meter
Specifications :
  • Voltage : 120 to 250 Volts A.C
  • H.P : 0.5 to 3.0 H.P

1P+OLP (DIGI)

Features :
  • Over Load Protection
  • With AMP and Volt Meter Digital
Specifications :
  • Voltage : 120 to 250 Volts A.C
  • H.P : 0.5 to 2.0 H.P

2P+MCB (DIGI)

Features :
  • Over Load Protection
  • With AMP and Volt Meter Digital
Specifications :
  • Voltage : 120 to 250 Volts A.C
  • H.P : 0.5 to 10.0 H.P

DOL-AUTO

Features :
  • Over Load Protection
  • On Delay Timer(Auto)
Specifications :
  • Voltage : 200 to 450 Volts A.C (Three Phase)
  • H.P : 0.5 to 10.0 H.P

PEG-6

Features :
  • Over Load Protection
  • On Delay Timer(Auto)
  • Amp + Volt Meter (Dual)
  • Mkl Type Contector & Relay
Specifications :
  • Voltage : 200 to 450 Volts A.C (Three Phase)
  • H.P : 0.5 to 6.0 H.P

PEG-10

Features :
  • Over Load Protection
  • On Delay Timer(Auto)
  • Amp + Volt Meter (Dual)
  • MU Type Contector & Relay
Specifications :
  • Voltage : 200 to 450 Volts A.C (Three Phase)
  • H.P : 0.5 to 20.0 H.P

PEG-20

Features :
  • Over Load Protection
  • On Delay Timer(Auto)
  • Amp + Volt Meter (Dual)
  • MU Type Contector & Relay
Specifications :
  • Voltage : 200 to 450 Volts A.C (Three Phase)
  • H.P : 10.0 to 30.0 H.P

PEG-20(IP)

Features :
  • Over Load Protection
  • On Delay Timer(Auto)
  • Amp + Volt Meter (Dual)
  • MU Type Contector & Relay
  • Dry Run Protection
Specifications :
  • Voltage : 200 to 450 Volts A.C (Three Phase)
  • H.P : 10.0 to 30.0 H.P

KP-SOLAR

Specifications :
  • Voltage : As Per Customer Required
  • H.P : 0.5 to 7.5 H.P
  • Input Voltage : D C
  • Output Voltage : A C

KP-APFC

Features :
  • Automatic Power Factor Protection
Specifications :
  • Voltage : 200 to 450 Volts A.C (Three Phase)
  • Range : 3 Kvar to 300 Kvar

KP-ATS

Features :
  • Over load Protection
  • With AMP and Volt Meter
  • Auto Transformer
Specifications :
  • Voltage : 200 to 450 Volts A.C (Three Phase)
  • H.P : 30.0 H.P to 300.0 H.P

1P+DRYRUN

Features :
  • Digital Amp + Volt Meter
  • Over Load Protection
  • Under Load Protection (Dryrun)
  • High Voltage Protection
  • Low Voltage Protection
Specifications :
  • Voltage : 120 to 250 Volts A.C
  • H.P : 0.5 H.P to 5.0 H.P

3P+DRYRUN

Features :
  • Digital Amp + Volt Meter
  • Over Load Protection
  • Under Load Protection (Dryrun)
  • High Voltage Protection
  • Low Voltage Protection
Specifications :
  • Voltage : 200 to 450 Volts A.C
  • H.P : 0.5 H.P to 7.5 H.P

DIGITAL AMP & VOLT METER

Specifications :
  • Amp : 0.0 To 100.0 Amp & 0.0 To 25.0 Amp
  • Volt : 0.0 To 250.0 volt & 0.0 To 450.0 volt

DIGITAL DRYRUN METER

Features :
  • Over Load
  • Under Load
  • High Voltage
  • Low Voltage
Specifications :
  • Amp : 4.0 To 20.0 & 10.0 To 60.0 Amp
  • Volt : 0.0 To 250 Volt & 0.0 To 450.0 Volt